Auxiliary boiler tube renewal
Created 02/07/2026, 13:15
Last Update 28 d ago
Reference Number
PO-85510
The auxiliary boiler (Aalborg OL-20, s/n 08-4421) developed a tube leak on the furnace side and was taken out of service after repeated low-water alarms. The attending superintendent's inspection confirmed two ruptured smoke tubes and heavy scaling on the surrounding rows. We required an approved boiler workshop to attend the vessel in Gibraltar, renew six smoke tubes, carry out a full waterside inspection, chemically descale the remaining tube nest, and hydrostatically test the boiler to class requirements before the vessel's next long voyage. Class attendance for the pressure test to be arranged by the owner, with all works carried out while the vessel was alongside for bunkering and stores.
Gibraltar, GIGIB
18/07/2026 - 21/07/2026
Boiler-survey-report-Jun-2026.pdf
Ruptured-tubes-photos.jpeg
Aalborg-OL-20-tube-diagram.pdf
IMO: 9612874
Product Tanker
Liberia